DESIGNMISSION 011 · Current sensing · Kelvin connectionsFoundational

Your Shunt Is Measuring the Copper Too

The load draws a verified 4.00 A. The board reports 5.60 A. Review the sense takeoffs, then release a correction within a 2.0% worst-case error budget.

Requirements

Four-terminal shunt · 10 mΩ ±1%Each force segment · 2 mΩAmplifier error allowance · ±0.5% of true current
  1. 01Inspect measurement path
  2. 02Release correction
Circuit overview

Force current and sense voltage

Top-side conceptual layout. B and C are dedicated sense terminals on a four-terminal resistor, not arbitrary points on two-terminal solder pads.

Four-terminal shunt and force copperCurrent flows left to right through two 2 milliohm copper segments and a 10 milliohm shunt. A and D are remote force nodes. B and C are dedicated sense terminals. Separate sense wires run to the amplifier selected inputs.RSH · 10 mΩ2 mΩ2 mΩ4.00 A →ABCDSENSE AMPIN+IN−

Supplied node potentials (C = 0 V): A 48 mV · B 40 mV · C 0 mV · D −8 mV.

Differential voltage 56.0 mVNominal indicated current 5.60 ASigned nominal error 40.0%
Model and limits

Bounded DC model: I = V / 10 mΩ. Conservative absolute worst-case sum: copper contribution + shunt tolerance allowance + amplifier allowance. No RSS/statistical cancellation is credited. Sense-input loading, offset, temperature drift, noise and internal connection residuals are excluded; the supplied amplifier allowance bounds its aggregate error here. B and C represent the resistor manufacturer's defined low-current sense terminals. Real accuracy still depends on the actual resistor terminal geometry, amplifier input behavior, temperature, and layout.

Current task
Current task

Step 1 of 2

Find what the amplifier measures

Compare A–D with B–C deliberately, including probe polarity. Which resistance lies inside each span, and which hypothesis explains the two readings?

0 evaluated decisions · Progress saved locally
Technical references