DEBUGPOWER CONVERSION / MISSION 010Intermediate

The Buck Converter Won't Behave

A TPS54331 supply produces 5 V at light load, but the rail collapses when the electronic load steps to the required 1.5 A. Establish which stage is failing, calculate the inductor stress, and approve a replacement without hiding the protection response.

Requirements

TopologyNon-synchronous buckInput12 VOutput5.00 V ±0.15 VRequired load1.50 ASwitching570 kHzIC current limit3.5–5.8 A specified rangeL1 installed10 µH · ISAT 1.00 A
  1. 01Characterize the failure
  2. 02Qualify L1
  3. 03Close the case
Circuit overview
SIMPLIFIED POWER STAGEU3 · TPS54331 · REV A
U3 · TPS54331570 kHz12V_INPHL1 · 10 µHISAT 1.00 AD4COUTLOAD0.2 / 1.5 A+5V_OUTTP1TP2TP3
Failure report: +5V passes the bench check at 0.20 A, then collapses when the required 1.50 A load is applied.
MEASUREMENT BENCHReady to measure
INSTRUMENT

Output after L1, probed at the load connector with a short ground spring.

Select a measurement target, then measure to inspect the result.

Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task
Technical references

Authoring reference: TI TPS54331 datasheet · Rev. H · sections 6.5, 6.6, 7.3 and 8.2.2.5.1. Device limits remain part-specific.