The Regulator Regulates the Wrong Point
A 12 V-to-3.3 V buck measures 3.30 V at its output pad, yet the remote load falls out of tolerance as current rises. Decide where the loop should sense, how that trace should return, and whether a fixed output offset is a safe substitute.
Requirements
Input · 12 VLoad · 0.25–1.5 ALoaded path · 80 mΩLoad limit · 3.25–3.35 VSense-line disturbance · ≤30 mV p-p
- 01Close the loop at the load
- 02Prove the regulation point
Circuit and case data
Authored measurement capture
Inspect and save the original case evidence before making a decision.
Select an artifact, inspect its contents, then save the observation.
Evidence notebook 0 saved
No evidence saved yet. Measure, inspect the result, then save useful observations.
Technical references
Implementation note
Use a dedicated, quiet trace from the intended regulation point. Keep it away from switching copper and avoid carrying load current in the sense route. Confirm the controller permits the added path and compensation.
Texas Instruments TPSM53604 datasheet · remote-sense layout example