DESIGNMISSION 013 · Power entry · Reverse polarityFoundational

Someone Reversed the Power Plug

A field controller must survive a backwards supply plug. Keep its ground continuous and protect the positive input without wasting the voltage and thermal budgets.

Requirements

Input · +9 to +24 V; reversal down to −24 VTotal load · 2.00 ADrop ≤0.20 V · junction ≤105°C at 60°C ambient
  1. 01Meet the protection budget
  2. 02Verify protection
Circuit overview

Selected circuit

High-side reverse-polarity protectionSeries diode anode at input, cathode at board. Ground is continuous.INPUTBOARD2.00 AD1Common ground remains continuous. D1 conducts from input to board.

The diode symbol shows forward conduction from anode to cathode. Trace it under both plug polarities. An enabled MOSFET channel can conduct in both directions; its diode direction does not provide bidirectional isolation.

Forward drop 0.45 VDevice loss 0.90 WEstimated junction 132.0°C

Conduction estimates are conditional on the supplied gate-drive envelope. Compare drive, gate stress, blocking rating, loss and thermal limits separately.

Circuit and case data
Circuit and case data
Operating assumptions and limits

High-side protection only. The board is initially discharged, ground stays connected, and no external signal or alternate supply can energize it. A supplied 1 kΩ output bleed bounds reverse-leakage voltage; the normal 2 A protected-path current includes bleed and gate-bias current.

Require 20% voltage-rating headroom above blocking and gate stress. Board characterization supplies 80°C/W junction-to-ambient for each candidate. Use hot on-resistance. This is a steady-state, initially discharged-board model. It does not qualify hot-plug transients, inrush, avalanche, surge/TVS coordination, SOA, or reverse-current isolation when another source keeps the board energized.

Part and gate-network data

These fictional P-MOS profiles guarantee the listed hot RDS(on) at |VGS| ≥4.5 V and have adequate 2 A current capacity. Reverse leakage ≤20 µA.

Blocking and gate limits
Part|VDS||VGS|Hot RDS(on)
Q-A40 V20 V60 mΩ
Q-B30 V8 V20 mΩ
Q-C40 V20 V200 mΩ
Q-D40 V20 V90 mΩ

Series diode D1: 40 V / 3 A, worst forward drop 0.45 V at 2 A, reverse leakage ≤10 µA. Its direction is fixed correctly; assess its remaining costs.

10 kΩ to ground + 10 V gate-source clamp

Clamp cathode to source, anode to gate. Supplied startup/steady-state envelope limits |VGS| to 10.5 V; forward operation guarantees at least 8.35 V drive.

10 kΩ to ground, no gate clamp

The gate stays near ground; source voltage can approach the 24 V input.

Tie gate directly to source

VGS = 0 V. The MOSFET channel remains off.

Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task

Step 1 of 2

Meet the protection budget

Drop = I × R; MOSFET loss = I² × R; diode loss = I × VF; estimated junction = ambient + loss × supplied thermal resistance.

0 evaluated decisions · Draft and verification saved locally
Technical references