DESIGNMISSION 014 · Power · Regulator thermalsIntermediate

More Copper, or a Different Component?

A controller works on the bench but its 5 V rail cycles in the hot chamber. Decide whether board copper can rescue the linear regulator, or whether the package or power architecture must change.

Requirements

VIN · 9–14 V5.00 V ±3% · 250 mA continuousAmbient · 60°CDesign junction ≤105°C
  1. 01Choose a power stage
  2. 02Verify design corners
Circuit overview

Derive allowable thermal resistance

Estimated junction temperature against the design ceilingThe selected U1 · legacy SOT-223 LDO with 400 mm² thermal region estimates 151.1 degrees Celsius, compared with a 105 degree design limit.AMBIENTHOTTER105°C LIMIT151.1°C60°C180°C
High-line loss2.278 WBoard θJA40°C/WRequired θJA≤19.8°C/WLow-line margin2.90 V

LDO loss = (VIN − VOUT) × IOUT + VIN × IQ. Junction estimate = ambient + loss × characterized θJA.

Circuit and case data
Circuit and case data
Design assumptions and limits

Use worst-case high line for dissipation and low line for regulation. The existing U1 is a SOT-223 LDO on the 400 mm² region. At 14 V it repeatedly enters thermal protection; at 9 V it regulates normally. The load is steady DC.

All device specifications and θJA values below are qualified for this board family and natural-convection enclosure. Copper area is capped at 900 mm². The θJA values are measured board/enclosure characterizations for this exercise, not package-only constants or a universal copper-area law.

Component and board data
Worst-case device data
DeviceInputOutputCurrentThermal input
U1 · legacy SOT-223 LDO6.1–20 V5 V ±2.0%0.50 A1.10 V dropout; 2.0 mA IQ
U2 · exposed-pad LDO5.35–20 V5 V ±2.0%0.50 A0.35 V dropout; 0.1 mA IQ
U3 · synchronous buck7–18 V5 V ±2.5%1.00 A86% power-stage efficiency; 25 mW control
Measured junction-to-ambient resistance on this board family
LayoutAreaU1U2U3
Compact land pattern100 mm²65°C/W52°C/W75°C/W
400 mm² thermal region400 mm²40°C/W30°C/W55°C/W
900 mm² thermal region900 mm²24°C/W18°C/W45°C/W
Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task

Step 1 of 2

First derive θJA(max) = (105°C − 60°C) / high-line loss. Then compare three intervention levels: retain U1 and change PCB copper; change package/device to U2; change architecture to U3. Use the characterized layout data, then check low-line regulation separately.

Compare intervention levels

0 evaluated decisions · Draft and verification saved locally
Technical references