DESIGNMISSION 032 · Power architecture · Rail sequencingIntermediate

One Supply, Two Rails

A sealed controller has one 12 V input, a 5 V sensor rail drawing 0.8 A, and a 3.3 V MCU rail drawing 0.25 A. Build a power tree that stays inside its heat budget, carries the loads with margin, and brings the sensor rail up before MCU logic can drive it.

Requirements

Input · 12 V5 V load · 0.80 A3.3 V load · 0.25 ALoss · ≤0.80 W Current margin · 25%Sequence · 5 V leads by ≥2 msStartup reason · avoid MCU drive into an unpowered 5 V interfaceLoaded rail tolerance · ±1%
  1. 01Architect the two rails
  2. 02Prove the system
Circuit overview

System power tree

12 V to 5 V and 3.3 V power tree12 V feeds both regulator inputs independently; each output supplies its own load. Both enables connect to input power. 12 V INPUT protected source 5 V LDO0.80 A output3.3 V LDO 0.25 A output IN OUT IN OUT SENSOR · 5 V 0.80 A · 4.00 W MCU · 3.3 V 0.25 A · 0.825 W EN EN ENABLES FROM INPUT Solid: power · Dashed: enable control · All stages share ground (not shown).

Calculated full-load model: the 5 V buck is 90% efficient and the 3.3 V buck is 88% efficient. LDO ground current is neglected. In the cascade, the 5 V buck supplies 0.80 A to the sensor plus 0.25 A to the LDO. Input power includes both stages. Startup times are authored scenario data, measured at 90% of each rail's nominal voltage.

Circuit and case data
Circuit and case data
Calculated power ledger
Useful load power4.83 W Input power 12.60 W Conversion loss 7.78 W Startup lead 0.0 ms

Minimum output-current rating: 5 V: 1.0000 A · 3.3 V: 0.3125 A. Full-load output demand × 1.25; the cascade includes the downstream LDO input.

An LDO’s voltage difference becomes heat. A converter’s current rating and its startup behavior remain separate release checks even after efficiency passes.

Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task

Step 1 of 2

Architect the two rails

0 evaluated decisions · Draft and evidence saved locally
Technical references

Engineering boundary

Power-good and enable pins are commonly used to coordinate rails. The exact thresholds, delays, discharge behavior and fault response belong to the selected regulator data sheets; this mission grades only this simplified full-load model and the supplied startup scenarios.

Texas Instruments LM3880 · rail sequencing context