Stop the Inductive Kick
A 24 V solenoid turns off through a 60 V low-side MOSFET. The original board reaches 82 V, while a plain flyback diode lets coil current decay too slowly. Design a turn-off path that protects the switch, meets the electrical decay limit, and survives the stored energy.
Requirements
- 01Balance clamp tradeoffs
- 02Verify turn-off
Circuit and case data
Authored measurement capture
Inspect and save the original case evidence before making a decision.
Select an artifact, inspect its contents, then save the observation.
Evidence notebook 0 saved
No evidence saved yet. Measure, inspect the result, then save useful observations.
Technical references
Design boundary
Integrated solenoid drivers similarly treat current regulation, recirculation and clamp behavior as part of the power path. This mission keeps the driver discrete so the stress, current-decay and energy tradeoff remains visible. Clamp voltage is an ideal constant reverse voltage across the coil and the pulse-energy choices are supplied network qualifications for this exact single-pulse envelope. They are not generic TVS datasheet energy ratings. Real selection requires clamp tolerance/dynamic resistance, pulse shape and repetition, temperature derating, parasitic overshoot, MOSFET SOA/avalanche and actuator tolerance.
Analog Devices · diode-plus-Zener demagnetization (Figure 4)