Make This Measurement Useful
A pressure sensor module supplies a conditioned, ground-referenced 5–45 mV output across a 0–10 Hz measurement band. The controller uses a 0–3.00 V ADC, while a 100 Hz interference component reaches the cable. Choose gain, bandwidth and an amplifier whose guaranteed input and output ranges make the complete channel useful.
Requirements
Sensor · 5–45 mVSignal · 0–10 HzInterference · 100 HzADC · 0–3.00 VRequired span · ≥2.40 VTop endpoint · ≤2.85 VFilter · nominal 22 Hz pole; tolerance review required
- 01Design the measurement channel
- 02Verify the complete channel
Circuit and case data
Evidence notebook 0 saved
No evidence saved yet. Measure, inspect the result, then save useful observations.
Technical references
Engineering boundary
A production channel also needs offset, bias-current, noise, resistor tolerance, stability, settling, ADC drive and anti-alias validation with the selected parts. This mission isolates range and first-order bandwidth decisions.