DESIGNMISSION 034 · Analog front ends · Gain and filteringIntermediate

Make This Measurement Useful

A pressure sensor module supplies a conditioned, ground-referenced 5–45 mV output across a 0–10 Hz measurement band. The controller uses a 0–3.00 V ADC, while a 100 Hz interference component reaches the cable. Choose gain, bandwidth and an amplifier whose guaranteed input and output ranges make the complete channel useful.

Requirements

Sensor · 5–45 mVSignal · 0–10 HzInterference · 100 HzADC · 0–3.00 VRequired span · ≥2.40 VTop endpoint · ≤2.85 VFilter · nominal 22 Hz pole; tolerance review required
  1. 01Design the measurement channel
  2. 02Verify the complete channel
Circuit overview

Measurement chain

Conditioned pressure-signal front endA conditioned, ground-referenced millivolt pressure signal passes through a non-inverting amplifier, low-pass filter and three-volt ADC.PRESSURE CHANNEL · 12 BITSENSOR OUTPUT5–45 mV0–10 Hz signalNON-INVERTING AMPA2GAIN · 40×1 + Rf / RgRC LOW-PASSfc · 80 HzADC0–3.00 V4096 codes100 Hz INTERFERENCEA useful measurement needs range, common-mode, output-swing and bandwidth checks together.

The stage uses a supplied first-order response and guaranteed amplifier boundaries. It is not an arbitrary op-amp stability or noise simulator.

Circuit and case data
Circuit and case data
Calculated design ledger
Output endpoints0.20–1.80 VADC span used1.60 V10 Hz loss0.07 dB100 Hz rejection4.09 dB

More gain is useful only until the high endpoint clips. A lower cutoff rejects more interference only until it removes wanted signal.

Guaranteed amplifier ranges

Supplied guarantees at the stated supply and load; the RRIO label alone is not qualification.

  • A1 · Input 0.00–3.30 V · Output 0.05–3.05 V
  • A2 · Input 0.20–3.10 V · Output 0.05–3.05 V
  • A3 · Input 0.00–3.30 V · Output 0.05–2.50 V

The nominal 22 Hz pole gives about 0.82 dB loss at 10 Hz and 13.36 dB rejection at 100 Hz. Component tolerance and anti-alias qualification remain separate release checks.

Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task

Step 1 of 2

Design the measurement channel

0 evaluated designs · Draft and evidence saved locally
Technical references

Engineering boundary

A production channel also needs offset, bias-current, noise, resistor tolerance, stability, settling, ADC drive and anti-alias validation with the selected parts. This mission isolates range and first-order bandwidth decisions.

Texas Instruments Precision Labs · ADC context