REVIEWMISSION 005 · PCB layout · DecouplingFoundational

The Capacitor Is There. Why Isn't It Helping?

An MCU resets during a repeatable fast load-step test even though its 100 nF decoupling capacitor is beside the package. Find the complete high-frequency current loop and review four supplied placement captures.

Requirements

Rail 3.3 VLimit ≤ 100 mV droopProbe U7 VDD–GNDReference solid L2 groundComparison same fixture + load step
  1. 01Explain Rev A
  2. 02Compare revisions
Circuit overview
POWER PLACEMENT VIEWL1 ROUTING · L2 SOLID GND
Rev A decoupling layoutAn MCU supply pin, local capacitor, ground via, and highlighted complete current loop.U7MCUFAST LOAD STEPVDDGNDC21100 nF · 0402GND VIA
VDD path Ground connection18.6 mm connection-path proxy
Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task
Technical references

Engineering notes

Complete path: capacitor → VDD → IC → ground → capacitor. Both connections must be short and low inductance.

The voltage traces are supplied fixture captures. Route length is a geometry cue, not a calculated inductance.

Reference: Analog Devices, MT-101: Decoupling Techniques.