DEBUGPOWER / MISSION 006Intermediate

It Works Until the Motor Starts

The controller boots and streams sensor data normally. When its 12 V motor starts, the motor twitches and the STM32F401 boot banner appears again. Use time-resolved power evidence to prove the reset chain before choosing a corrective direction.

Requirements

Input 12 V / 1.00 A limitMCU STM32F401 · BOR Level 3BOR falling 2.75–2.88 VMotor run 0.42 ACapture window 40 ms
  1. 01Inspect the event
  2. 02Build evidence
  3. 03Diagnose + correct
Circuit overview
SYSTEM UNDER TESTMOTOR ENABLE @ 8 ms
SUPPLY12 V · 1 AREG3V3MCUSENSOR STREAMMOTOR0.42 A RUNTP1TP2TP3TP4TP5
Observed: motor twitches, telemetry stops, then the MCU boot banner appears again.
MEASUREMENT BENCHReady to measure
INSTRUMENT

Board input after the connector, referenced to power-entry ground.

Select a measurement target, then measure to inspect the result.

Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task
Technical references

Device reference and case limits

The STM32F401 Level-3 brownout range comes from the STMicroelectronics STM32F401 datasheet. The source limit, rail collapse and timed captures are authored evidence for this board; the clipped current trace does not size a replacement source.