DESIGNMISSION 027 · Low power · Energy budgetsFoundational

The Battery Must Last Longer

A wireless condition tracker works correctly but lasts days instead of the required year. It wakes for a two-minute measurement and upload each day. Build a complete current budget, then choose the architecture that makes the long sleep interval actually low power.

Requirements

Battery · 1000 mAh nominalUsable · 850 mAhActive · 30 mA for 120 s/dayWake-to-ready · ≤50 msTarget · ≥365 days
  1. 01Design the duty cycle
  2. 02Close the energy budget
Circuit overview

Product energy path

Battery-powered tracker energy path and daily current timelineA battery and regulator feed an MCU, sensor and radio. A short active event sits above a long sleep interval, followed by a life-target gauge.BATTERY850 mAh usableREGULATORlegacyMCUSENSORRADIOONE DAY · ACTIVE BLOCK NOT TO SCALEACTIVE · 120 sSLEEP · 86,280 sESTIMATED LIFE · 11 d / 365 d target

The 30 mA active capture is measured at the battery/input side of the complete system. All sleep terms are battery-referred currents, including regulator IQ and the 10 µA board base load.

Circuit and case data
Circuit and case data
Battery-terminal sleep budget
Board base10 µAMCU2000 µASensor1000 µARegulator IQ80 µATotal sleep current3090 µAWake-to-ready time0.2 msActive charge / day1.000 mAhSleep charge / day74.057 mAh
Live lifetime worksheet
Sleep floor3090 µADaily average3127.4 µAEstimated life11 days

Life uses the supplied usable capacity, not the nominal label: usable mAh ÷ complete average mA ÷ 24. The 850 mAh usable capacity is already the exercise's derated battery budget. The 30 mA active state is measured at the battery/input terminals of the complete powered measurement/radio event. Every sleep term is also battery-referred, including regulator IQ; no output-side current is mixed into this battery-current budget, and the 120 s/day active window includes wake and sensor-ready time. Self-discharge, pulse-voltage sag, temperature, battery aging and converter efficiency variation are outside this first-order average-current model.

Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task

Step 1 of 2

Design for the complete duty cycle

0 evaluated decisions · Draft and evidence saved locally
Technical references

Measurement boundary

Do not infer long-term life from the active pulse alone or from one DMM reading. Verify the current waveform, integrate active energy, measure the stable sleep floor and confirm that every powered component enters its intended state.