5 V Sensor, 3.3 V MCU
A pressure sensor can output 0–5 V, but the MCU ADC runs from 3.3 V. Choose two provided standard 1% resistors that satisfy the ADC operating window across resistor tolerance, keep the ADC node below the stated 3.6 V stress ceiling at the 5.25 V high-input case, and meet loading and acquisition constraints.
Design requirements
All four must pass. R TOP is between the sensor and ADC; R BOTTOM is between the ADC and ground.
- 01Build design
- 02Verify design
Technical references
Exercise boundary. The 3.6 V limit is an authored stress ceiling, not a permitted conversion range. This exercise does not validate clamp current, power-off injection, sensor output impedance, the ADC sample-time model behind the authored 10 kΩ limit, temperature drift, or transient protection. A real design needs the chosen ADC’s operating limits and protection specifications.
Engineering notes
Voltage: VADC = VIN × RBOTTOM ÷ (RTOP + RBOTTOM)
Loading: The sensor supplies the divider current: I = V IN / (R TOP + R BOTTOM).
ADC drive: The ADC sees the divider's Thévenin resistance: R TOP || R BOTTOM. Lower source resistance helps the ADC sample capacitor settle to the required voltage.
Tolerance corners: the 5.0 V operating window is checked at both resistor-ratio extremes; the 5.25 V stress case uses R TOP at −1% and R BOTTOM at +1%. Loading uses the high-input / low-resistance corner, and acquisition uses both resistors at +1%.
Reference: TI, SAR ADC input settling (SBAA531). The 10 kΩ acquisition ceiling is supplied for this exercise, not a universal ADC limit.