REVIEWMISSION 020 · ESD · Protection layoutIntermediate

The Protection Part Is in the Wrong Place

Follow a connector strike through the copper and release a TVS placement, routing and return path supported by characterized captures.

Requirements

Interface · 12 Mbit/sProtected pin · ≤12 VNeighbor reset · ≤1.5 VFixture · characterized A/B capture
  1. 01Release a protection layout
  2. 02Verify the surge path
Circuit overview

Layout under review

ESD protection layout under reviewConnector J1 feeds protected input U4. The selected TVS position, line route and ground return are highlighted.J1FIELD I/OU4PROTECTED ICTP-U4RESET · UNPROTECTED NEIGHBORD21 TVSCHASSISBONDDIGITAL GND VIA FIELDIEC FIXTURE · ±8 kV

The TVS part number does not change between revisions. Only placement, signal topology and the discharge return change.

Circuit and case data
Circuit and case data
Supplied characterization
U4 input peak35.1 VNeighbor reset peak9.2 V

Residual and neighbor-net peaks are fixed results from the supplied A/B fixture cases; each complete layout combination has its own authored capture. They are not calculated from trace length or a universal PCB-inductance formula. The short chassis/shield return is valid because this exercise explicitly supplies a nearby connector shield/chassis bond. Real products must use the actual enclosure and grounding architecture. Passing still requires system-level testing on production hardware.