DESIGNMISSION 017 · Power sequencing · Back-poweringIntermediate

The Board Is Off, but the Signal Is Still On

The host keeps sending a 1 MHz clock after the sensor board shuts down. The sensor rail rises to 2.78 V anyway. Stop the back-power path without destroying the powered signal edge.

Requirements

Host · 3.3 V / 50 ΩTarget VDD · may be 0 VOff rail · ≤ 0.2 VInjected current · ≤ 0.5 mAPowered edge · ≤ 100 ns
  1. 01Separate the power domains
  2. 02Verify both power states
Circuit overview

Cross-domain signal path

Live host connected to an unpowered sensor boardThe host drives an optional target-powered buffer, followed by the series resistor and target input. A direct link bypasses the buffer.HOST · ON3.3 V · 1 MHzDIRECT LINKR SERIES1 kΩSENSOR INPUTVDD = 0 VD CLAMPUNPOWERED TARGET RAILInput clamp path and isolation are shown separately.

The target input model has a clamp beginning 0.45 V above its rail and an equivalent 2 kΩ unpowered rail load. These are supplied scenario values. The selected interface must also preserve the 30 pF line’s powered edge.

Circuit and case data
Circuit and case data
Power-state contract and datasheet
Required behavior at every target power state
StateTarget railInterface output
Off≤ 0.2 VHigh impedance
Ramp0–3.3 VHigh impedance until power-good
On3.3 V valid1 MHz clock, ≤100 ns edge

Topology: HOST → selected buffer or direct link → series resistor → TARGET. Buffered powered-edge calculations use a supplied 50 Ω output resistance; direct paths use the host's 50 Ω. Buffers use the target 3.3 V domain. Compare the available OE ownership arrangements during off, ramp and powered operation.

Supplied buffer profiles
PathPower-off leakageSupplied delay
Generic buffer · supplied profileNot supplied3 ns
SN74LVC1G125 buffer≤10 µA4.7 ns

The direct-path clamp model is a bounded DC/RC approximation. The powered timing budget conservatively adds 2.2 × output resistance × capacitance and the supplied propagation delay; this authored envelope is not a datasheet rise-time guarantee. Real partial-power-down qualification must also check the exact device Ioff conditions, input/output voltage limits, OE behavior during ramp, connector sequencing, ESD, and signal integrity.

Calculation model
Off current934.4 µAOff rail1.869 VPowered edge69.3 ns

For a direct link, use host resistance, series resistance and the 2 kΩ off-rail load. Buffered edge calculations use the output-side resistance and 30 pF target load. A generic buffer has no supplied off-state current bound; use the actual candidate data.

Evidence notebook 0 saved

No evidence saved yet. Measure, inspect the result, then save useful observations.

Current task
Current task

Step 1 of 2

Separate the power domains

0 evaluated decisions · Draft and verification saved locally
Technical references